Home - Knowledge - Details

How a Brushless DC Motor Commutates: Six-Step, Hall and Sensorless

A brushless DC motor cannot run on a fixed voltage the way a brushed motor can. The winding that should be energised changes as the rotor turns, and something has to decide when to switch it. That decision is commutation. Get it right and the motor behaves like a DC motor with a straight speed-torque line; get it wrong and it stalls, stutters or refuses to start.

Why the current has to be switched at all

In a brushed motor, the commutator does this mechanically. The brushes ride on a segmented ring that rotates with the rotor, so the connection to each coil reverses at exactly the right angle, automatically, with no electronics involved. It is elegant, and it is the reason a brushed motor needs only two wires and a battery.

A brushless motor moves the windings to the stator and the magnets to the rotor, so there is nothing rotating to reverse the current. The switching has to be done outside the motor, by transistors, and those transistors have to be told when to fire. The whole control problem is answering one question: where is the rotor right now?

The six states of a three-phase winding

A three-phase BLDC motor has three windings, and at any moment one is driven positive, one is driven negative and the third is left floating. Six combinations of those three roles cover a full electrical revolution, so six-step commutation steps through six states in sequence, each one held until the rotor has moved far enough that the next combination produces more torque than the current one.

Two consequences follow, and both matter for selection. Torque is not perfectly smooth, because between states the alignment between the magnetic field and the rotor is not ideal, so a small ripple appears at six times the electrical frequency. And the motor cannot start from an arbitrary position without knowing where it is, because the wrong first state can push the rotor backwards rather than forwards.

Hall sensors: three of them, 120 electrical degrees apart

The common way to answer the question is to fit three Hall-effect sensors inside the motor, spaced 120 electrical degrees apart, watching the rotor magnets pass. Each sensor gives a high or a low, and the three together give six distinct patterns - one per commutation state. The controller reads the pattern, looks up the state, and fires the matching transistors. Our 22 mm and 28 mm frames are available with this arrangement, and the Hall board is fitted at build time rather than added afterwards.

Hall sensing is simple and it works from zero speed, which is why it suits applications that start under load: a valve that has to break away from a seat, a pump that has to lift a column of fluid, a mechanism that has to move from a hard stop. The cost is three signal wires in the cable and a small board inside the motor, both of which have to be designed in before the winding is frozen.

Sensorless: back-EMF and the start-up problem

A spinning motor generates a voltage on its own windings, proportional to speed. That back-EMF can stand in for the Hall sensors: by watching the floating phase, the controller can tell where the rotor is without any sensor at all. Fewer wires, fewer parts, and nothing to fail inside the motor.

The catch is that back-EMF is proportional to speed, so at standstill it is zero and there is nothing to read. A sensorless drive has to start blind, by forcing the motor through a preset sequence and hoping the rotor follows, then handing over to back-EMF sensing once it is turning fast enough to produce a signal. On a fan or a propeller that works well, because the load is light at low speed and the rotor catches quickly. On a pump or a valve it often does not, and the motor can rock back and forth without ever starting.

This is the single most common misunderstanding we correct. Whether the drive is sensorless has to be settled before the winding is fixed, because the phase timing and the lead configuration are set at that point and cannot be changed by firmware afterwards.

Six-step against sinusoidal and FOC

Six-step is the simplest scheme, not the only one. Two smoother alternatives turn up whenever noise or low-speed smoothness dominates.

Scheme What it gives you What it asks for
Six-step with Hall sensors starts under load, simple firmware, cheap drive visible torque ripple and a slight tick at low speed
Six-step sensorless two wires out of the motor, nothing inside to fail poor starting under load; needs a light rotor to catch
Sinusoidal or FOC smooth torque and quiet operation at low speed position feedback, a faster processor, more commissioning

Field-oriented control is not automatically better. It earns its cost where the shaft has to turn slowly and evenly - a gimbal, a medical drive, a fan whose noise is audible in a room - and it is overkill on a pump that runs at one speed. The choice belongs with the electronics team, but it has to reach us before the motor is specified, because a sinusoidal drive wants a different winding than a six-step drive.

The three parameters that decide the scheme

  • What the motor has to start against. A free propeller and a pump full of fluid are different starting problems. If there is load at zero speed, sensorless is the wrong choice and no amount of tuning will rescue it.
  • The lowest speed the application must hold. Six-step with Hall sensing holds low speed well; sensorless loses its signal as speed falls; sinusoidal needs position feedback to hold slow speed smoothly.
  • How much the drive may cost and how much space it has. Three signal wires, a sensor board and a connector are real costs, and so is the processor headroom that FOC needs.

Where the choice shows up

Fans and propellers are the natural home of sensorless six-step: light rotor, no load at start, and a cost target that rules out sensors. Pumps and valve actuators need Hall sensing because they start against pressure. Gimbals and medical drives move to sinusoidal control because the noise and the smoothness are the product. Handheld tools sit in between and are usually decided by the drive cost rather than by the motor.

Questions we get about commutation

Can a sensorless motor be converted to Hall sensing later?

Not on the same unit. The sensor board, the lead count and the phase timing are all fixed when the motor is built, so converting means a new build with a new part number. That is why the drive scheme has to be settled at enquiry stage rather than at commissioning.

Why does my motor stutter at start-up but run fine once going?

That is the classic sensorless start-up signature: the drive is forcing a sequence before back-EMF is available, and the rotor is not following it. It shows up when the load at standstill is heavier than the drive assumed. The fix is either Hall sensors or a drive with a proper open-loop ramp, and the second is a firmware change the motor supplier cannot make.

Does six-step commutation cause the ticking noise?

Partly. Torque ripple at six times the electrical frequency produces a low-level tick that becomes audible at slow speed, and the transition between states adds a small step. Moving to sinusoidal drive removes most of it. If the noise is mechanical rather than electrical, it is usually the gearbox rather than the commutation.

The 28 mm brushless frame is the one most of these enquiries settle on, and the brushless DC motor range page covers the windings it is available in.

Tell us what the motor starts against

Send Inquiry